Scenario
The new sales floor has four desk phones on SW1. The switch can give 30 W in total, and it books 15.4 W for every phone by default, because it does not know how much a phone really needs. After the first phone the budget is gone, so the other three stay dark. The phones also need their own voice VLAN, VLAN 100, next to the data VLAN 10.
Topology
Requirements
- 1VLAN 100 exists and is named VOICE
- 2Fa0/1 to Fa0/4 use VLAN 100 as the voice VLAN and keep VLAN 10 for data
- 3All four phones are powered (show power inline says on)
- 4The power budget of SW1 is not exceeded and no port is denied for lack of power
SW1 has its data VLAN and four access ports with a phone on each. Type show power inline and show cdp neighbors, then start with: enable
R1> show running-config
CCNA lab · about 15 min
IP phones on PoE and the voice VLAN
Four IP phones are plugged into a switch with a small power budget. Only one of them wakes up. Find out why, give each phone its power and its voice VLAN.
This lab is included in the CCNA plans and in the free trial.